Inspections

Inspections

  • Footing Inspection: Performed after forms are in, before footings are poured; setbacks to property lines must be verifiable.

  • Foundation Inspection: Performed after forms are in; bond outs and rebar installed.

  • Backfill Inspection: Performed after forms are removed, damp proofing applied, perimeter drains, stone and filter fabric in place & before placement of backfill. 

  • On-site Subsurface Wastewater Disposal System: Minimum of 2 inspections – first at scarification of bed bottom; second when disposal bed, tank and distribution box, or pump station is installed but not buried. 

  • Internal Plumbing Inspections: sub-slab piping installations prior to concrete pour; above grade rough-in; required test (air or water) must be on.

  • Complete Rough-In Inspection: Includes the combined individual inspections for framing, plumbing and electrical rough-in prior to insulating and close-in.

  • Framing Inspection: Performed after any electrical and plumbing is roughed in, and after all framing, fire-stopping, draft stopping and bracing are in place. 

  • Electrical Inspection: Performed prior to insulation and/or close-in.

  • Electrical Temporary Service (one ground rod minimum)

  • Electrical Permanent Service (two ground rods in place and panel is bonded)

  • Insulation Inspection (prior to covering/close-in): Insulation and air barrier; U-Value of windows; air sealing of all infiltration sources/penetrations in thermal envelope

  • Fire Separation in garage (required only if materials can not be verified at final)

  • Final Inspection: This inspection must receive final approval for the issuance of a Certificate of Occupancy (when required) before the space can be occupied or used. This is the official end of the building permit process.